SOMATOM Definition Flash

Ultrarapide. Avec une dose minimale.

SOMATOM Definition Flash
 
Nous contacter

Things you can only do with a SOMATOM Definition Flash

There are unique benefits The SOMATOM® Definition Flash scanner has to offer to you and your patients. Read on to find out what things you can only do with a SOMATOM Definition Flash.

Pediatric chest & body CT. Without sedation.

Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 0.34 s
Scan length: 99 mm
Rotation time: 0.28 s
Heart rate-independent temp. resolution: 75 ms
Tube settings: 120/120 kV, 5 mAs/rot
Eff. dose: 2.3 mSv

Chest CT. Without breath-hold.

Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 1.3 s
Scan length: 586 mm
Rotation time: 0.28 s
Heart rate-independent temp. resolution: 75 ms
Tube settings: 100/100 kV, 362 mAs/rot
Eff. dose: 3.7 mSv

Triple rule-out. Routinely below 2 mSv.

Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 0.6 s
Scan length: 290 mm
Rotation time: 0.28 s
Heart rate-independent temp. resolution: 75 ms
Tube settings: 100/100 kV, 370 mAs/rot
Eff. dose: 1.9 mSv

Diagnostic image quality. For patients up to 307 kg.

Collimation: 32 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 31 s
Scan length: 480 mm
Rotation time: 0.5 s
FoV: 780 mm
Tube settings: 120/120 kV, 741 mAs
CTDlvol: 60.11 mGy
Patient weight: 181 kg

Trauma examinations. 1640 mm in under 5 seconds.

Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 3 s
Scan length: 986 mm
Rotation time: 0.28 s
Heart rate-independent temp. resolution: 75 ms
Tube settings: 140 kV, 200 mAs/rot

Neuro and coronary CTA. Just one scan.

Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 2.07 s
Scan length: 571 mm
Rotation time: 0.28 s
Heart rate-independent temp. resolution: 75 ms
Tube settings: 120/120 kV, 182 mAs/rot
Eff. dose: 8 mSv

Dose neutral Dual Energy. Always a second contrast.

Collimation: 64 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 12 s
Scan length: 287 mm
Rotation time: 0.33 s
Tube settings: 100/140 kV, 50/60 mAs
Eff. dose: 2.6 mSv

Dose neutral Dual Energy. Saves an extra scan.

Collimation: 32 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 28 s
Scan length: 642 mm
Rotation time: 0.5 s
Tube settings: 100/140 kV, 81/68 mAs
Eff. dose: 6.2 mSv

Routine sub-mSv heart. Even in patients up to 90 kg.

Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 0.28 s
Scan length: 128 mm
Rotation time: 0.28 s
Heart rate-independent temp. resolution: 75 ms
Tube settings: 80/80 kV, 300 mAs/rot
Eff. dose: 0.4 mSv
Patient weight: 88 kg

CT TAVI Planning. With only 40 mL contrast.

Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 1.5 s
Scan length: 724 mm
Rotation time: 0.28 s
Heart rate-independent temp. resolution: 75 ms
Tube settings: 100/100 kV, 258 mAs/rot
Eff. dose: 1.7 mSv

All heart rates. No exclusions.

Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 4 s
Scan length: 96 mm
Rotation time: 0.28 s
Tube settings: 100 kV, 265 mAs/rot
Eff. dose: 3.6 mSv
Heart rate: 48–107 bpm

Myocardial stress perfusion. Blood flow and volume.

Collimation: 32 x 1.2 mm
Spatial resolution: 0.30 mm
Scan time: 28 s
Scan length: 72 mm
Rotation time: 0.3 s
Tube settings: 100 kV, 370 mAs/rot
Eff. dose: 9.6 mSv

Cardiac Dual Energy. At 75 ms temporal resolution.

Collimation: 64 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 10 s
Scan length: 132 mm
Rotation time: 0.28 s
Tube settings: 100/140 kV, 164/140 mAs/rot
Heart rate: 44–60 bpm



Multiply your potential

The SOMATOM Definition Flash offers the widest advanced clinical portfolio ever in CT: From dose-neutral Dual Energy CT to whole organ perfusion. Find out how these ground-breaking innovations turn into unique benefits in daily clinical CT practice.

Stellar Detector

The SOMATOM Definition Flash, with its two fully integrated Stellar Detectors, generates ultra-thin slices with very high spatial resolution for an extremely high level of visual detail, but is also designed for ultra-low-signal imaging. Its unprecedented image quality can enhanceobese imaging as well as low-kV examinations in pediatric and Dual Energy imaging.

C-Level view

C-level executives are faced with some challenges when it comes to purchasing new CT scanners. They have to run a successful and prosperous business while also taking the best possible care of their patients. Today’s devices – like the SOMATOM Definition Flash – offer many more options, and training and service become the keys to successfully exploiting your investment’s maximum potential.

Being FAST

Be FAST: Fully Assisting Scanner Technologies make time-consuming and complex procedures faster and accelerate your workflow to new levels. With the FAST platform, the SOMATOM Definition Flash delivers the shortest possible time from positioning the patient on the CT table to reviewing the first images. This gives medical professionals more time to take better care of their patients.

Taking CARE

Take CARE: Combined Applications to Reduce Exposure provide you with brilliant image quality at the lowest possible dose. It makes CT safer, especially for the most sensitive patients like women and children. With the new CARE platform, the SOMATOM Definition Flash can lower radiation exposure to previously unheard-of levels.

Pediatric CT

Although radiation exposure is getting lower with conventional CTs, the use of sedation, anesthesia, and controlled ventilation is still very common. These come with risks and drawbacks, especially for children. The SOMATOM Definition Flash with the new FAST CARE platform automatically ensures an unparalleled low dose in all examinations. With its unrivalled patient-friendliness and safety, Flash Spiral scanning makes sedation and controlled ventilation a thing of the past.

Oncology CT

Oncology CT poses its own challenges to clinicians. Patient preparation, accumulated dose, and the monitoring of chemotherapy or anti-angiogenesis treatments make oncology CT anything but easy.
The SOMATOM Definition Flash’s low-dose capabilities, its ability to scan without breath-hold, its Dual Energy applications, and the potential for covering whole organs for CT perfusion make it the preferred device for radiation therapy planning and monitoring.

Trauma CT

Immediate whole-body CT scanning is of the essence during the "golden hour” of trauma. But unwanted patient motion, limited scan ranges, and time-consuming patient preparation create unnecessary stress in the trauma bay.
Get the most out of the golden hour with the SOMATOM Definition Flash – in every patient. Its unmatched Flash Spiral scan speed of 458 mm/s, its immense power reserves, and the highest temporal resolution all act together to freeze motion while delivering the industry’s highest spatial resolution.

Neuro CT

Neuro CT ranges from plain non-contrast, over spine, and inner-ear to whole-brain CT perfusion imaging. Separating vessels safely from bone, differentiating fresh from old bleeding, and reconstructing spine and discs is difficult and time-consuming. The SOMATOM Definition Flash, including FAST CARE and Dual Energy, always offers a second contrast, lets you perform whole-brain perfusion and dynamic angiographies up to 48 centimeters, and its iterative reconstruction redefines image quality and low-dose neuro CT imaging.

Cardiac CT

The heart is the organ that has been challenging generations of CTs. Patient exclusion is high because of high and irregular heart rates. The SOMATOM Definition Flash allows you to scan any patient independent of heart rate and also provides Dual Energy information. In addition, it quantifies the hemodynamic relevance of a stenosis for sound and sustainable treatment decisions.

Dual Energy CT

Dual Energy CT (DECT) is one of the most exciting developments in radiology in recent history. The SOMATOM Definition Flash Dual Source CT, which applies all state-of-the-art dose-saving techniques for Dual Energy, delivers dose-neutral imaging with unlimited applications for all possible clinical fields, including the heart.



Clinical images

The SOMATOM Definition Flash scanner has the fastest volume acquisition speed and highest heart rate-independent temporal resolution on the market. Two revolutionary Stellar Detectors enable sharp images with a routine spatial resolution of 0.30 mm.

Excellent coronary stent imaging

HR-independent temp. resolution: 75 ms
Collimation: 2 x 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 4 s
Scan length: 107 mm
Rotation time: 0.28 s
Tube settings: 100/100 kV, 160 mAs/rot
CTDIvol: 3.6 mGy
DLP: 38.52 mGy cm
Eff. dose: 0.5 mSv

CT TAVI planning

HR-independent temp. resolution: 75 ms
Collimation: 2 x 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 1.5 s
Scan length: 724 mm
Rotation time: 0.28 s
Tube settings: 100/100 kV, 258 mAs/rot
DLP: 209 mGy cm
CTDIvol: 2.68 mGy
Eff. dose: 1.7 mSv

Triple rule-out

HR independent temp resolution: 75 ms
Collimation: 2 x 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 0.21 s
Scan length: 264 mm
Rotation time: 0.28 s
Tube settings: 100/100 kV, 294 mAs
DLP: 98 mGy cm
CTDIvol: 3.06 mGy
Eff. dose: 1.4 mSv

High-resolution lung imaging
Collimation: 2 x 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 1 s
Scan length: 335 mm
Rotation time: 0.28 s
Tube settings: 100 kV, 82 mAs
DLP: 153 mGy cm
CTDIvol: 3.80 mGy
Eff. dose: 2.1 mSv

Abdominal imaging with dissection

Collimation: 2 x 64 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 2 s
Scan length: 500 mm
Rotation time: 0.28 s
Tube settings: 120 kV, 90 eff. mAs
DLP: 300 mGy cm
CTDIvol: 6 mGy
Eff. dose: 4.4 mSv

Obese imaging

Collimation: 2 x 32 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 31 s
Scan length: 480 mm
Rotation time: 0.5 s
Tube settings: 120 kV, 741 eff. mAs
FOV: 780 mm
CTDIvol: 60.11 mGy
DLP: 2959 mGy cm
Patient weight: 400 lbs

Excellent Neuro image quality

Collimation: 2 x 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 6 s
Scan length: 153 mm
Rotation time: 1.0 s
Tube settings: 100/100 kV, 500 eff. mAs
CTDIvol: 66.35 mGy
DLP: 1015 mGy cm
Eff. dose: 2.1 mSv

Whole-brain perfusion

Collimation: 2 x 32 x 1.2 mm
Spatial resolution: 0.30 mm
Scan time: 45 s
Scan length: 76 mm
Rotation time: 0.57 s
Tube settings: 80 kV, 200 mAs
CTDIvol: 256 mGy
DLP: 3036 mGy cm
Eff. dose: 6.3 mSv

Pediatric chest CT

Collimation: 2 x 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 0.3 s
Scan length: 189 mm
Rotation time: 0.28 s
Tube settings: 70 kV, 81 eff. mAS
Eff. dose: 0.8 mSv
Patient: 4-year-old child

Pediatric Dual Energy

Collimation: 2 x 64 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 2 s
Scan length: 118 mm
Rotation time: 0.28 s
Tube settings: 80/Sn 140 kV, 26/16 mAs
DLP: 18 mGy cm
Eff. dose: 1.6 mSv
Patient: 7-month-old baby

Metal implant follow-up

Collimation: 2 x 32 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 7 s
Scan length: 134 mm
Rotation time: 0.5 s
Tube settings: 100/140 kV, 99/305 mAs
CTDIvol: 4.3 mGy
DLP: 253 mGy cm
CTDIvol: 16.94 mGy
Eff. dose: 3.8 mSv

DE virtual non-contrast CT

Collimation: 2 x 32 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 28 s
Scan length: 642 mm
Rotation time: 0.5 s
Tube settings: 100/140 kV, 81/68 mAs
DLP: 432 mGy cm
CTDIvol: 6.55 mGy
Eff. dose: 6.2 mSv