CentraLink Data Management System

Deliver quality lab results faster for better patient care

CentraLink Data Management System
Nous contacter

Up to 15 user workstations
Up to 32 instruments



  • Multiple LIS connections:  Downloads work orders to ADVIA Automation Solutions
  • Manages work-order query from instruments
  • Acts as a work-order buffer for automation systems
  • Uses multiple communication protocols (ASTM, Spec 79, HL7)
  • Supports the following instrument interfaces from Siemens:
  1. Automation: VersaCell® System, ADVIA® Automation
  2. Immunoassay: ADVIA Centaur® XP Immunoassay System, ADVIA Centaur® CP Immunoassay System
  3. Chemistry: ADVIA® 2400 Chemistry System, ADVIA® 1800 Chemistry System, ADVIA® 1650 Chemistry System, ADVIA® 1200 Chemistry System, IMMULITE® 2000 XPi Immunoassay System
  4. Integrated Systems: Dimension® Xpand® Plus Integrated Chemistry System, Dimension® EXL with LM Integrated Chemistry System, Dimension Vista® 1500 Intelligent Lab System, Dimension Vista® 500 Intelligent Lab System
  5. Hematology: ADVIA® 2120i Hematology System with Autoslide, ADVIA® 120 Hematology System
  6. Molecular: VERSANT 440 Molecular System
  7. Hemostasis: Sysmex® CA-1500 System, Sysmex® CA-7000 System


Operating System

Microsoft Windows® 2003 Server

User Interface
Standard Windows® navigation via drop-down menus and icons

Order Entry
Simplified order entry for LIS backup

Options to review all, review none, or review by exception
Customizable review for:

  • Range (definable by age, sex, species)
  • Delta checking (percentage & absolute basis)
  • QC violations
  • Instrument flags

Dispositioning options for:

  • Automatic or manual results entry and validation
  • Rerunning, omitting, or editing results
  • Manually entering differential results
  • Adding comments to results

Display options for configuring results order and viewing hematology cytograms

Quality Control

  • By method, instrument, species, lot or moving average
  • Data display as results or Levey-Jennings plots
  • Westgard rules (1-2s, 1-3s, 10-x, 2-2s, 4-1s, R-4s)
  • Adding comments during review
  • Support for using comparators (<,>)
  • Omit data from statistical calculations
  • Configurable interval for automatic QC exports
  • Real time upload to BioRad Unity System


Search by:
       Sample ID
       Physician name or ID
       Patient name or ID
       Instrument or instrument group, test, or sample status

Multi-language Support
Configure language preferences for each connected workstation (English, French, Italian, German, Spanish)


  • Set multiple standard and user-defined access levels
  • Define menu options for each access level
  • McAfee Antivirus Enterprise Version 8.5i and higher
  • CentraLink standard IT security configurations


Create custom report formats for headers, footers, column headings, and test display order

Data Storage
Accommodate up to 30,000 samples and QC records per interfaced instrument*

Produits ou Services associés

*ADVIA CentraLink Data Management System version 12.0 required